Regarding the spreader 80t for the Shuttle Lift straddles we need some more details:
1. Shuttle lift pulley blocks dimensions in order to clearly understand how to fabricate our spreader. See the circle in the attached drawing, we have to design those parts.
2. We would use hydraulic components instead of electric ones (as for the 150t capacity spreader), they are more suitable for this application. Of course a micro power pack will be positioned on the spread itself and maintaining all features agreed. It is just better, nothing different is required to you.
3. Hoisting travel dimensions: what is the max hoisting travel for the straddle carrier you are going to install this spreader? We have to provide the cable reel.
4. The min and max required longitudinal travel (check the attached drawing – “longitudinal travel”). Please check and let me know if they are the same required for the 150t spreader or different.