Impact tests may be carried out immediately
after moulding, whilst heat distortion temperature (HDT), strength, and stiffness tests
may be carried out after sub-Tg annealing or long periods of storage at ambient
temperatures. For example the yield stress of UPVC increases from 55 MPa when tested
one hour after moulding to 57 MPa when tested 85 hours after moulding