This study used a two-frame
cross-correlation configuration, also illustrated in Fig. 2,
where a synchronised digital camera acquired two consecutive
images separated by a short time interval. Each image
comprised only one pulse of laser light that was sufficiently
fast to ‘freeze’ the motion of any objects lying within the
illuminated field of view