HF2 280516 update CIP new protocol shift 00-08 validation change flavor from Pungent to non pungent = Aloe apple to MM orange
1.Mixing room 5 step (AC101+hot water)
Water+Hot AC101+Water+Hot water+water no issue
2.JBT loop
Water+Hot AC101+Water+Hot water+water no issue
(CIP protocol set include hot water step)
3.Filler+FB pasteurized
Water+Hot AC101+Water
Fail found left flavor @final rinse water
Next step
Add #1 Water+Hot water+water still found left flavor
Add #2 Water+Hot water+water ok-no issue
4.Bit pasteurized
Water+Hot AC101+Water
Fail found left flavor
Next step
Add #1 Water+Hot water+water still found left flavor
Add #2 Water+Hot AC101+water
Ok-no issue
*hot water temp. 82 C
Assumption
Only caustic 3 step without hot water maybe not enough for pungent flavor
Next test
Retest 3 step Caustic with change flavor from MPO (non pungent to other)@ filler,FB pasteurized,
Bit pasteurized
(JBT CIP protocol set + hot water step.)
Mixing loop test 3 step caustic some object and monitor if ok apply for other object
Any concern pls suggest.