2.5. Viscosity measurements
Viscosity measurements of selected samples were performed using a dynamic shear rheometer with a 25 mm diameter vane geometry in a cup with a diameter of 27 mm, Bohlin (Malvern, UK), using a shear rate profile from 0.1 to 100 s1. All measurements were performed at 25 C.