(a) Single-Wall Viewing. For materials and for welds in
components, a technique may be used in which the radiation
passes through two walls and only the weld (material)
on the film side wall is viewed for acceptance on the radiograph.
When complete coverage is required for circumferential
welds (materials), a minimum of three exposures
taken 120 deg. to each other shall be made.