To compare the experimental and calculated concentrations of
the compounds in the column outlet phases, the number of ideal
stages required for rice bran oil deacidification was calculated
based on the operational and equilibrium free fatty acid concentrations
in the raffinate stream (Eq. (1)). This approach is valid when
the operating and equilibrium curves are both linear over a given
concentration range