The positions of the auxiliary and working electrodes would
also affect the attachment of the liquid drop cell and effective
surface area of the electrode for electrochemical generation of
iodine. If the auxiliary electrode was arranged to be on the upper
position relatively to working electrode, effective surface area of
the working electrode was found to be better, since liquid drop cell
prefers to attach to the hydrophilic glass body of auxiliary
electrode