Fig. 11 shows the resistance variation with the moist air at the
ambient temperature. The humidity range was 20–90%RH (Relative
Humidity). The resistance of the elements is normalized at the
initial change of gas flow. Almost 15% decreased at the range of
20–40%RH. After 40%RH, resistance does not change significantly
when humidity is increased.