Using the circuit shown in Figure 5-3, set the load resistance per phase at 629 ohms, and with E1=300 volts, adjust the capacitive reactance until the load voltage is as close as possible to 300 V. Measure E1,P1, Q1, E2,P2, Q2 , E3 and the phase angle