The photos were sent to Germany and here is the response :
Quote:
Thanks for the photos. Based on the photos can explain why it has come to the leak very easily.
It is clearly visible that the built by us as transit protection hose clamp was not removed after installation.
Thus, the kink protection effect which leads to a damage of the tube.
This also applies to the other on the photos for discerning hoses, please immediately remove all clamps can to prevent further damage!
There is sticker on the terminals of pointed forward to remove the clamps after installation.
Because it is so clearly a mounting error, we cannot accept the complaint.
Unquote: