ABSTRACT
Chapter J of the 2010 AISC Specification recommends the use of either single- or double-sided minimum half-depth transverse web stiffeners
where web crippling strength is less than design concentrated load; use of a doubler plate of minimum half-web depth is also suggested
in the Specification. Commentary on the Specification mentions that because the web crippling phenomenon has been observed to occur in
the web adjacent to the loaded flange, a half-depth stiffener (or stiffeners) or a half-depth doubler plate is needed to eliminate web crippling.
Research conducted at the University of Maine, however, clearly showed that web crippling can occur even in webs having half-depth stiffeners.
Further, the AISC Specification does not have a formula to predict crippling strength of webs with partial-depth stiffeners under local
compressive loads. This paper presents a formula for evaluating crippling strength of webs with partial-depth stiffeners that considers the
effect of depth of stiffener, width of load and eccentricity of loading.