In measurement of machined surfaces featuring a series of lays at a regular interval, such as those finished by milling or turning, it is sometimes the case that less than five peaks or valleys are included in a recommended evaluation length. In this case, a false measurement results with the error message "L-P" ("LESS PEAK") on the display. To solve this problem, use an evaluation length at least six times longer than interval of the lays.