Count Mode Timing Waveforms
The counter-compare module can generate compare events in all three count modes:
• Up-count mode: used to generate an asymmetrical PWM waveform.
• Down-count mode: used to generate an asymmetrical PWM waveform.
• Up-down-count mode: used to generate a symmetrical PWM waveform.
To best illustrate the operation of the first three modes, the timing diagrams in Figure 16 through Figure 19
show when events are generated and how the EPWMxSYNCI signal interacts.