Bar spacing and bar diameter could affect the correlation graphs. Covermeters from different manufactures could also cause certain variation. Correlation for particular project (particular bar spacing and bar diameters) and the covermeter to be used can greatly improve cover measurement accuracy. Correlation is recommended if greater cover measurement accuracy is required, i.e. a structure subject to aggressive environment and concrete durability is the major concern.