Factors leading to an underestimation of the actual NO2, level are as follows:
-Increasing exposure period, for example, the average of 2 consecutive 2-week exposures gives a higher
reading than a single 4-week exposure, attributed to degradation of the absorbed nitrite. Failure to completely extract nitrite during post- exposure processing