2.3. Shear test
Single shear method by compressive test type was adopted to evaluate the shear strength properties of
nail joints attacked by fungi. It was tested by universal testing machine with loading speed of 2mm/min in
Figure 3. The load and slip displacement were measured by load cell and transducer, respectively.