The corrosion rate of aged alloy N06022 in
this oxidizing solution increases gradually as
the aging time and the aging temperature (T)
increase, for T ≥ 538 °C (1000 °F). For samples
aged at 482 °C (900 °F) the corrosion rate
remains the same, even after aging for 10,000 h
(Fig. 13).