The electric energy consumptions of building with the High Solar Reflective Paint coating are
compared with the conventional paint coated (white and white grey color shade) and uncoated
building. These results are compared from experimental day that have a same temperature ambient
from all operating condition, as shown in Fig. 8. The High Solar Reflective Paint coating building
obviously uses the electric energy less than the conventional coated and uncoated building. The r
electric consumption is lower than another coated building because of high sunlight reflecting
performance. The lower heat energy that transfers to the building causes the lower load of the air
conditioner.'When comparing the saving energy during small building coated with white and white
grey color found that the percentile of saving energy of smhll building which coated with white color
has a higher value than white grey color in all condition cases because of high efficiency in reflect the
solar ray. White high Solar Reflective Paint coated building can save the electric energy range 25-30Yo
of the conventional paint coated building consumption and range 35-40o/o of the uncoated building consumption. For the white grey, the high Solar R.eflective paint coated building can save the electric
energy range 19-30o/o of the conventional paint coated building consumption and range 30-38% of the
uncoated building consumption.