The endurance strength (1E6 cycles) of the frame was found to be 2403 m (microns) [10] corresponding to a stress of
478 MPa. From the stress based design the allowable open-hole location was found to be around 45 mm from its initial location,as shown in Fig.12(a).However the fracture mechanics approach was necessary to ensure are liable location for frame holes.