This is also where the curtain wall system vertical expansion
joint is located. In the horizontal direction, there are total of
eight expansion joints, each allowing typically about 56 mm of
combined open and closing movement. Special considerations
were given to fire protective requirements of the Curtain Wall
Support System (CWSS), and additional allowances had to be
provided to total vertical and horizontal movements