Comparing the effective stress valuescalculated versus the strength of the AISI/SAE 4140 steel, at the region of the spline filet, the yield strength of the half-shaft(665 MPa) was surpassed by the effective stress, which is related to a torque of 590 Nm (65% of the 950 Nm designrequirement).