The trial lot from BSSC have been run in BTMT. The ply analysis done by Pholsun as the attached. As the informed from their technical, they found tip rise around 10mm in the cutting process. Normally they control at < 5mm and 10mm is at the maximum limit.
Furthermore problem! They also found flare at the cord end as the attached. This problem detected at the building process. Currently they already produced for 2000m and hold 800m in the spool. The 2000m will continue to the process with special monitor and testing in the final product.