Upward movement of the dresser cannot be confirmed. When the dresser actually moves upward, adjust the space between the leading edge of the upwaed confirmation proximity switch and the dog (0.5 to 1.0 mm). If the dresser stays to be lowered, check the solenoid valve. If the alarm activates during automatic grinding operation, move the table tothe right end with the table handle.