Specific Tests:
Raw Material Inspection for cable.
Electrical test for continuity and isolation, it must be done with automatic test bench fitted out with antagonist plug.
Electrical test for isolation following one of these two protocols:
o Protocol A: at 2U+1000V minimum during 1mn minimum (U=300vac minimum, threshold current at 30mA maximum)
or
o Protocol B: at 2(U+20%)+1000V minimum during 1s minimum (U=300vac minimum, threshold current at 30mA maximum)
Isolation test for power cables:
Between “GND” and “P” pin of plug.
Between “GND” and “N” pin of plug.
Final inspection cable for batch identification
4. Mandatory Marking and Records
Record raw material Certificate by batch
Batch identification (date code...)
Isolation and Continuity mark up
Cable routing (OMS Rev.)