It was confirmed that there is no adsorption of EDTA onto
the filters. If a filtered river sample was filtered again and the
filter was treated with phosphate, no adsorbed EDTA could be
detected. Figure 4c shows a typical chromatogram from a
sediment extraction. It was checked by standard addition that
the peak corresponds to EDTA.