There are many calculations to be performed in this Lab. Therefore, it will be more efficient to
take the time to completely set up Data Studio™ before starting the lab activities.
1. Measure the total mass of the dynamics cart and the attached force sensor. Record this mass, m.
2. Set up Data Studio™ to read the data collected from the force sensor connected to the
dynamics cart and the motion sensor located at the end of the 1.2 meter track. The motion
sensor does not need to be calibrated but the force sensor does. Always remember to
first remove all tension and then press the TARE button to re-zero the force sensor
before data is taken for each trial.
3. Change “Sampling Options” so that Periodic Samples = 50 Hz. Change the motion detector’s
Trigger Rate so that it is also 50 Hz.
4. Open the Experiment Calculator (click on the calculate button) and define the calculation for Kinetic
Energy, K= ½ mv2.