The monitored battery voltage input is fed to two voltage dividers, R1, R2 and R3 for the OFF adjustment and R4, R5 and R6 for the ON adjustment. The fixed resistors are chosen so that the pots cover the expected adjustment range (2-3 volts for R2 and 4-6 volts for R5) and make the adjustment easier.