The incremental inductance and dc resistance can be calculated
based on the ideal assumptions that the winding and the
core are in circular shape and the effective flux density throughout
the core is the average value of Bmax and αBmax. Therefore,
the energy stored in the CFI can be calculated by integrating the
flux density throughout the total core volume