X-ray diffraction (XRD) patterns of H-ZSM-5 zeolites were
recorded on a Rigaku RINT2400 diffractometer using Cu-K radiation.
Quantitative measurements of the Si/Al ratio were performed
using inductively coupled plasma-atomic emission spectroscopy
(ICP-AES) using a Rigaku JY 38S spectrometer.
Before the measurements,
the prepared zeolites were dissolved in HF solution. The
N2 adsorption measurements were carried out at 77K on a Coulter
SA3100
The specific surface areas were calculated by the BET equation.
External surface areas and micropore volumes were calculated
by the t-plot method.
Adsorption measurements of C6 alkanes (n-hexane, 2-
methylpentane, 2,3-dimethylbutane) were performed gravimetrically
using a microbalance with a quartz spring.
The volume of
adsorption was calculated by using the liquid density.
The initial
adsorption rate of 2,3-dimethylbutane was calculated by the following
equation: (initial adsorption rate) = (amount of adsorbed
2,3-dimethylbutane at 2 min)/2
Prior to the measurement, 0.10 g
of the zeolite sample was degassed for 30 min under vacuum at
773K. After being cooled to 273K, the sample was exposed to the
constant pressure of the adsorbate vapor.
The number of acid sites
in H-ZSM-5 was obtained gravimetrically by the chemisorption of
diethyl amine at using the microbalance in a similar manner to the
C6 alkane adsorption.
After the sample was exposed to the constant
pressure of the diethyl amine vapor at 273K until saturation, it was
subsequently evacuated at 573K for 30 min to remove any weakly
adsorbed diethyl amine molecules.
Then the sample was exposed
to the vapor of diethyl amine at 273K again. The difference in the
adsorption uptakes between first and second measurements was
considered to be the amount of chemisorbed diethyl amine.
The amount of coke formed on the zeolites during n-hexane
cracking was determined by thermo gravimetry (TG) using an SII TG/DTA 7200
The sample was heated from room temperature to
1073K at a ramping rate of 10K min−1 under the flow of air
The weight loss from 673K to 973K was used to obtain the amount of
coke on the zeolites.
X-ray diffraction (XRD) patterns of H-ZSM-5 zeolites wererecorded on a Rigaku RINT2400 diffractometer using Cu-K radiation.Quantitative measurements of the Si/Al ratio were performedusing inductively coupled plasma-atomic emission spectroscopy(ICP-AES) using a Rigaku JY 38S spectrometer.Before the measurements,the prepared zeolites were dissolved in HF solution. TheN2 adsorption measurements were carried out at 77K on a CoulterSA3100The specific surface areas were calculated by the BET equation.External surface areas and micropore volumes were calculatedby the t-plot method.Adsorption measurements of C6 alkanes (n-hexane, 2-methylpentane, 2,3-dimethylbutane) were performed gravimetricallyusing a microbalance with a quartz spring.The volume ofadsorption was calculated by using the liquid density.The initialadsorption rate of 2,3-dimethylbutane was calculated by the followingequation: (initial adsorption rate) = (amount of adsorbed2,3-dimethylbutane at 2 min)/2Prior to the measurement, 0.10 gof the zeolite sample was degassed for 30 min under vacuum at773K. After being cooled to 273K, the sample was exposed to theconstant pressure of the adsorbate vapor.The number of acid sitesin H-ZSM-5 was obtained gravimetrically by the chemisorption ofdiethyl amine at using the microbalance in a similar manner to theC6 alkane adsorption.After the sample was exposed to the constantpressure of the diethyl amine vapor at 273K until saturation, it wassubsequently evacuated at 573K for 30 min to remove any weaklyadsorbed diethyl amine molecules.Then the sample was exposedto the vapor of diethyl amine at 273K again. The difference in theadsorption uptakes between first and second measurements wasconsidered to be the amount of chemisorbed diethyl amine.The amount of coke formed on the zeolites during n-hexanecracking was determined by thermo gravimetry (TG) using an SII TG/DTA 7200The sample was heated from room temperature to1073K at a ramping rate of 10K min−1 under the flow of air The weight loss from 673K to 973K was used to obtain the amount ofcoke on the zeolites.
การแปล กรุณารอสักครู่..

X-ray diffraction (XRD) รูปแบบของ H-ZSM-5
ซีโอไลต์ถูกบันทึกอยู่ในRigaku RINT2400 diffractometer ใช้รังสี Cu-K. วัดเชิงปริมาณของศรี / อัตราส่วนอัลได้ดำเนินการโดยใช้สเปกโทรสโกการปล่อยinductively คู่พลาสม่าอะตอม(ICP-AES ) โดยใช้สเปกโตรมิเตอร์ Rigaku JY 38S. ก่อนที่จะวัด, ซีโอไลต์เตรียมละลายในสารละลาย HF การวัดการดูดซับ N2 ได้ดำเนินการที่ 77K ในโคลเตอร์SA3100 พื้นที่ผิวจำเพาะนี้จะถูกคำนวณจากสมการพนัน. พื้นที่ผิวภายนอกและปริมาณ micropore ถูกคำนวณโดยวิธีเสื้อพล็อต. วัดการดูดซับ alkanes C6 (n-เฮกเซน 2 - methylpentane, 2,3-dimethylbutane) ได้ดำเนินการ gravimetrically ใช้ไมโครกับฤดูใบไม้ผลิควอทซ์. ปริมาณการดูดซับที่คำนวณโดยใช้ความหนาแน่นของของเหลว. เริ่มต้นอัตราการดูดซับของ 2,3-dimethylbutane ที่คำนวณได้จากต่อไปนี้สมการ( อัตราการดูดซับเริ่มต้น) = (จำนวนดูดซับ2,3-dimethylbutane 2 นาที) / 2 ก่อนที่จะมีการวัด 0.10 กรัมของตัวอย่างซีโอไลท์ที่ถูกdegassed เวลา 30 นาทีภายใต้สูญญากาศที่773K หลังจากที่มีการระบายความร้อนที่จะ 273K, ตัวอย่างได้สัมผัสกับความดันคงที่ของไอดูดซับ. จำนวนของเว็บไซต์กรดใน H-ZSM-5 ที่ได้รับ gravimetrically โดยทางเคมีของเอdiethyl ที่ใช้ไมโครในลักษณะที่คล้ายกับC6 การดูดซับเคน. หลังจากที่ตัวอย่างได้สัมผัสกับค่าคงที่ความดันของไอเอ diethyl ที่ 273K จนอิ่มตัวมันก็อพยพต่อมาที่573K เป็นเวลา 30 นาทีในการลบอย่างอ่อน ๆโมเลกุลเอ diethyl ดูดซับ. จากนั้นกลุ่มตัวอย่างได้สัมผัสไอของ diethyl amine ที่ 273K อีกครั้ง ความแตกต่างในการดูดซึมการดูดซับระหว่างการวัดครั้งแรกและครั้งที่สองได้รับการพิจารณาให้เป็นจำนวนchemisorbed diethyl เอมีน. ปริมาณของโค้กบนซีโอไลต์ระหว่างเฮกเซนแตกถูกกำหนดโดยเทอร์โม Gravimetry (TG) โดยใช้ SII TG / DTA 7200 กลุ่มตัวอย่างที่ถูกความร้อนจากอุณหภูมิห้องเพื่อ1073K ในอัตราที่กระโจนของ 10K-1 นาทีภายใต้การไหลของอากาศการสูญเสียน้ำหนักจาก673K 973K จะถูกใช้ในการได้รับปริมาณของโค้กในซีโอไลต์