For the purposes of creating a finite element solution, the inductor is placed at the center of
a 2" by 2.5" box. On the boundaries of the domain, a boundary condition of A=0 is defined.
For the purposes of performing the finite element analysis, a current of 1 A is somewhat
arbitrarily applied to the coils. A fairly coarse mesh density with the mesh size constrained
to be no larger than 0.05" is defined everywhere. The meshed problem domain is pictured in
Figure