2.2.3. MTBE adsorption on GAC, zeolite and zeolite composites (batch experiments)
A solution of MTBE (2.3 mg/L) was added to Teflon centrifuge tubes (no headspace) containing the zeolite, PDADMAC-zeolite, PAM-zeolite, ODTMA-zeolite or cesium-zeolite composites (1 g/L). The tubes were agitated for 1–24 h in which equilibrium was reached [4,18]. Measurements were also taken after 1, 2 and 4 hand no significant increase in adsorption was obtained after 2 h. Super- natants were separated by centrifugation (10,000g for 10 min) and analyzed by GC/MS headspace to determine MTBE concentrations. Tests indicated that there was no sorption of MTBE on the Teflon centrifuge tubes and no volatilization of MTBE. The experiments were performed in triplicate.
2.2.3 การดูดซับสาร MTBE ใน GAC, ซีโอไลท์และคอมโพสิตซีโอไลท์ (ทดลองชุด)
วิธีการแก้ปัญหาของ MTBE (2.3 มก. / ลิตร) ถูกบันทึกอยู่ในหลอด centrifuge เทฟลอน (ไม่ headspace) ที่มีซีโอไลท์, PDADMAC-ซีโอไลท์, PAM-ซีโอไลท์, ODTMA-ซีโอไลท์หรือซีเซียม คอมโพสิต -zeolite (1 กรัม / ลิตร) หลอดถูกตื่นเต้นสำหรับ 1-24 ชั่วโมงที่สมดุลก็มาถึง [4,18] วัดยังถูกนำมาหลังวันที่ 1, 2 และ 4 มือไม่มีการเพิ่มขึ้นอย่างมีนัยสำคัญในการดูดซับที่ได้รับหลังจาก 2 ชั่วโมง natants ซุปเปอร์ถูกแยกจากกันโดยการหมุนเหวี่ยง (10,000g เป็นเวลา 10 นาที) และวิเคราะห์โดย headspace GC / MS เพื่อตรวจสอบความเข้มข้น MTBE การทดสอบแสดงให้เห็นว่ามีการดูดซับสาร MTBE ในหลอด centrifuge เทฟลอนและระเหยของสาร MTBE ไม่มี การทดลองดำเนินการในเพิ่มขึ้นสามเท่า