A STM/AFM (Omicron, Germany) system was used in UHV
(7 · 1011 Torr) to analyze the SS sheet both before and after
the CNT growth, to investigate down to the nanometric scale
the substrate surface roughness. The measurements were
performed at room temperature in constant current mode
with I = 0.3 nA, VSample = 700 mV.