For a fixed thermal load and allowed pressure drop, the heat
transfer coefficient per unit pressure drop is the most meaningful
comparison criterion. Thus from above comparison it is seemingly
that the usage of continuous baffle does not provide attractive
advantage in its thermal performance apart from its complicated
manufacturing process.