In the filter housing, the charge of the filter element will be opposite in sign to that of the fluid. The charge on the fluid will be transmitted downstream, and if enough charge is accumulated, the fluid dielectric constant is exceeded. The discharge then occurs to a conductive part of the filtration or fluid system that is lower in magnitude, resulting in potential damage to that part of the system. The extent of damage will depend on the material involved and the magnitude of the generated charge.