Flexible cables (coil technique using a flexible cable)
This is a technique of magnetization in which a current carrying cable is tightly wound
around the component. It favours the detection of flaws lying parallel to the cable Figure 7.6. The
area to be inspected should lie between the turns of the coil thus formed. The coil shall be moved
over the component at coil length intervals to ensure that the specified coverage is achieved.