1.Lubricate mold number: Count mold opening times. The oil pump starts when mold opening times reach the set value.
2.Lubrication Total time: the total time spent in this lubrication.
3.Lubrication time : the output of the repeated operation with the total time for lubrication.
4. Lubrication intermittent : the interval of the repeated operation with the total time for lubrication.
5. Cycle Wait time : during auto process, it is the time between completed thimble movement and starting a movement of moulds clamping of next cycle.
6. Cycle time : the time limitation to operation cycle in automatic process. The system alarms [ cycle time is over ] when the real operating time is longer than cycle time limitation .
7. Movement time limitation : the max time permitted when output movement.
8. Error alarm bell : the max time when error output occurs. To avoid long time alarming, the bell stops alarm when time is over.
9. Alarm interval : the time between alarm output and stop in alarm time.
10. Lubrication process: Asti shows in the follow chart. During the output time of lubrication. If it fails to detect any lubrication pressure signal, it would trigger an alarm, telling that the lubrication is failing if " opping working" after the failing of lubrication is chosen, then it would stop lubricating and would change to work in manual mode and stop the engine after the cycle of the alarming