Another important optimization was the stator axial thickness. A thicker stator will allow more turns of wire, increasing the output voltage, however it will also require a greater rotor spacing distance. As the rotors are spaced further apart, more flux from the magnets will tend to “short circuit” to the adjacent magnets, rather than traverse the stator to the magnet on the opposite stator