TEST PROCESS: UNDERTAKE PEEL TESTS ON THE HINGE, GAS STRUT BRACKETS, LOCK MOUNT BRACKET AND SASH (FOR 6600133 DOOR) AT BOTH ENDS OF THE GLUED ON COMPONENTS. THE ADHESIVE MUST TEAR WITHIN ITS THICKNESS ie.MUST REMAIN BOTH ON THE GLASS AND ON THE BRACKETS (CO-HESIVE FAILURE IS REQUIRED).
USE A WEDGE AND MALLET TO BEND COMPONENTS AWAY FROM THE GLASS AND WEAR GLOVES AND EYE PROTECTION WHEN UNDERTAKING THIS TEST.