With 60 slots occurring with 1 revolution then, since 1 revolution is a rotation of 360 ~ the minimum angular displacement, i.e. the resolution, that can be detected is 360/60 = 6 . The resolution typically varies from about 6 to 0.3 or better. With the incremental encoder, the number of pulses counted gives