The output-voltage control loop must changes slowly the inputcurrent reference, Iref, in relation of the current control loop action in order to avoid the interference of the outer control loop. Fig. 11 shows the control-to-input current transfer
function in terms of the duty-ratio. There, can be observed that for frequencies near 10 kHz the duty-cycle variationeffect can be neglected.