Cleaning Recommendations
Electrically isolate the machine before cleaning.
Never use a wet solution to clean the indicator panel.
Daily
• All exterior panels to be wiped over with normal cleaning solution for worktops, etc. (soapy water)
and then dried.
• The best results are obtained by opening the lid which allows full access to the seating and the
lid seal.
• All internal surfaces are automatically cleaned by the machine. Failure to do so must be
investigated.
Weekly (As Required)
• The lid seating area should be scrubbed with a brush, wiped and the neoprene seal washed with
the same cleaning solution.
Lubrication
The machine is designed for minimum maintenance.
• The clip bushes used in this machine must not be lubricated.
• Apply anti-seize compound if indicated.
• The motor is fitted with sealed for life bearings.
• The mechanical seal face must be perfectly clean.
• Use only clean water to lubricate the seal face.