The disintegration test was performed using an I.P.'85 disintegration apparatus, with distilled water at 37±0.5°. All tablet property values are shown as averages of five determinations. The complete disintegration time in the mouth was measured in five healthy volunteers. The end point for the disintegration in the mouth is the time when the tablet placed on the tongue disintegrates until no lumps remain. While testing, the volunteers kept the tablets motionless on their tongues [13] .