I had a good look at the drawing. It all looks good except the tolerance on the plan view. We won’t accept the +-10mm This is far too much, the sheetmetal will not wrap around if this is the case. I remember we discussed this issue some time ago and agreed that (+-3mm) is acceptable for coil lengths 1000-2000mm so this should be less than that.
Craig was quoted 85mm as min bend radius in an email from Artapol in December, please review.