EQUIPMENT:
1. Sampler: membrane filter, 37-mm , 0.8-:m MCE, 5-:m PVC, 2-:m PTFE, or glass fiber
filter, with cellulose backup pad in two-piece filter cassette.
NOTE 1: High concentrations of oil mist may plug membrane filters. Glass fibers filters have a higher capacity for oil mist and membrane filters.
NOTE 2: Handle filters carefully with tweezers to avoid contam ination by skin oil.
2. Personal sampling pump, 1 to 3 L/min, with flexible connecting tubing.
3. Infrared spectrophotometer, doulble beam, dispersive, with scanning capability in the 3200-2700 cm-1 region, and two 10-m m spectrophotometer cells, infrared quartz with PTFE stoppers mounted in demountable cell holders.
NOTE: Standard glass cells maybe used if infrared quartz cells are not available.
4. Vials, scintillation, 20-mL, with foil-lined or PTFE-lined caps.*
5. Volumetric flasks, 10-, 25-, and 50-mL.*
6. Volumetric pipet or reagent dispenser, 10-m L.*
7. Pipets, 2- to 250-:L.
8. Tweezers.
* Rinse glassware with CCl4. Air dry
 
Equipment: 
1 ตัวอย่าง: เมมเบรนกรอง 37 มม 0.8-: m MCE, 5-: m พีวีซี 2: m PTFE หรือใยแก้ว
กรองด้วยเบาะสำรองเซลลูโลสในสองชิ้นเทปกรอง. 
หมายเหตุ 1: ความเข้มข้นสูงของน้ำมัน หมอกอาจเสียบกรองเมมเบรน ฟิลเตอร์ใยแก้วมีกำลังการผลิตที่สูงขึ้นสำหรับหมอกน้ำมันและฟิลเตอร์เมมเบรน. 
หมายเหตุ 2:. ใช้ฟิลเตอร์อย่างระมัดระวังกับแหนบเพื่อหลีกเลี่ยงการ ination contam น้ำมันผิว
2 ปั๊มสุ่มตัวอย่างส่วนบุคคล 1 ถึง 3 ลิตร / นาทีด้วยการเชื่อมต่อท่อที่มีความยืดหยุ่น. 
3 spectrophotometer อินฟราเรดคาน doulble, กระจายที่มีความสามารถในการสแกน 3200-2700 CM-1 ภูมิภาคและสองเซลล์ spectrophotometer 10 มม, ควอทซ์อินฟราเรด stoppers PTFE ติดตั้งในมือถือของผู้ถือต่อพ่วง. 
หมายเหตุ: เซลล์แก้วมาตรฐานอาจจะใช้ในกรณีที่ผลึกอินฟราเรด เซลล์จะไม่สามารถใช้ได้. 
4 ขวด, ประกาย, 20 มลด้วยหมวกฟอยล์เรียงรายหรือ PTFE เรียงราย. * 
5 ขวดปริมาตร 10, 25 และ 50 มล. * 
6 ปิเปตปริมาตรหรือตู้น้ำยา 10-M ลิตร * 
7 Pipets, 2- ไป 250:. L 
8 แหนบ. 
* ล้างแก้วด้วย CCl4 อากาศแห้ง