6) Front and rear drive chain guide rail guide plate and stainless steel rails each after one month to apply a grease, choose ZG-2H calcium base grease (SY1409-16), when applied to remove the front cover and left and right rear cover, on the transmission chain angle position the applicator to the drive plate, which is brought into the guide and stainless steel rail.
Chapter 7 Repair
1. Common faults and trouble shooting machine
1) The power indicator light does not shine, all motor does not start
Reason: a power outage or air switch
2) Power indicator light, all of the motor will not start
Reason: emergency stop button did not return, clockwise rotation of emergency stop button, make its return
3) No water pump
Reason: the water tank water pump or pump power socket, plug contact
4) Feeding and discharging conveyor chain sends out the different bang
Reason: the conveyor chain in foreign body, conveying chain relaxation or conveyor chain deformation
2. Safety of machine repair
1) The machine should be in the power-off state of repair, and in the power switch-in hang on " repair, do not close valve " warning sign
2) Machine repair, do not pull cable, cable insulation layer should not be broken
After the completion of repair tools, should be counted, should not be left in the machine tool, to prevent the boot failure.
Chapter 8 Electrical fault processing method
1. Electrical safety instructions
If a fault occurs need electric cabinet mechanical inspection, must power off to open cabinet
2. Electrical equipment handling, transportation and storage
1) According to the electric cabinet weight, use the correct method of handling
2) Please do not be electrical cabinets and other objects stacked
3) Please don't drag motor cable, shaft to carry
4) Not in the cabinet interior into the metal iron filings and other conductive material or oil and other flammable objects.
3. Electrical equipment repair and safety precautions
1) The wiring or the inspection work, must first off, after ten minutes, until the voltage meter and the indication lamp is extinguished, the millimeter after confirmation, otherwise it may cause an electric shock
2) Wiring and inspection operations, the need for specialized technical personnel
3) Do not use wet hand operated switch, can lead to electric shock
4) Do not damage or strong pulling cable, can lead to electric shock
5) Not in the electrical cabinet. Debris, especially flammable, beware of fire