Assumptions 1 The flow is steady and incompressible. 2 The forces acting on the piping system in the horizontal direction are negligible. 3 The atmospheric pressure is disregarded since it acts on all surfaces.
Analysis We take the pump as the control volume, and the inlet direction of flow as the positive direction of x axis. The momentum equation for steady one-dimensional flow in the x (flow) direction reduces in this case to