VELOCITY PROFILE, OBSERVED
The velocity traverse is situated at a distance of 240.4 in., or 78 pipe diameters, downstream of the
pipe entrance, a distance sufficient the ensure fully developed flow at this point. Velocity head is measured
by means of an open ended total head tube, facing the air flow, of outer diameter 0.035 in and bore 0.020 in.