High-purity copper is immune to stress corrosion cracking in most environments and in
the practical range of service stresses. However SCC of high-purity copper in specific
corrosion environments has been documented [1–4]. Relating this fact to segregation of
trace impurities at the grain boundaries is not convincing because of the two observed