At the stationary sampling sites, the inhalable dust concentrations were exceeded during work tasks inside the boilers but not in work tasks outside the boilers, and inhalable dust concentrations were mainly below the OEL for inorganic dust. Maintenance and ash removal workers were exposed to Al and Mn, the concentrations of which exceeded the OELs by 38–80% in the workers’ breathing zone samples.